ROCKWOOL FirePro® AIS Sealant (Pack of 25 - 310ml Cartridges)
FirePro® AIS is a fire-resistant ablative sealant that is part of a fire-stopping solution to reinstate the fire performance of walls and floors | Sold as a pack of 25 - 310ml Cartridges.
Description
Key Points:
- Classified in accordance with BS EN 1366-3: 2021+A1: 2024.
- Tested in accordance with BS EN 1366-4: 2021.
- Classified in accordance with BS EN 13501-2: 2023.
- Tested in accordance with BS EN ISO 10140-2: 2021 (airborne sound insulation).
- Certified by UL-EU, Certificate No. UL-EU-01364-EN.
- Tested in accordance with ASTM E2923-14 (longevity assessment of fire-stop materials).
Description:
FirePro® AIS is an acrylic-based fire resistant ablative sealant, designed for use as part of a
fire-stopping solution to reinstate the fire performance of walls and floors. Suitable for linear joints up to 60mm wide.
This product should NOT be allowed to come into direct contact with cPVC type piping.
FirePro® AIS can be used as both a fire resistant seal within construction joints and to seal FirePro CB50 within penetration seals. Designed to reinstate the fire resistance of compartment walls and floors, FirePro® AIS provides fire resistance of up to 4 hours (EI 240) in accordance with EN 1366-4:2021, subject to the application.
Areas of application:
- Flexible and rigid walls.
- Rigid floors.
- Within CB50 batt penetration seals.
- Linear joints in walls and floors up to 60mm wide.
- Non-combustible pipes with insulation.
- Cable penetrations.
- Rigid conduits.
Fire performance:
- Designed to reinstate the fire resistance of compartment walls and floors, FirePro® AIS provides fire resistance of up to 4 hours (EI 240) in accordance with EN 1366-4:2021, subject to the application.
FirePro® AIS has been certified by UL, Certificate No UL-EU-01364-EN. - Please go to the bottom of this web page to access further information on fire performance.
Acoustic performance:
- Please refer to UL Certificate: UL-EU-01364-EN for further information on acoustic performance and air permeability.
- Please go to the bottom of this web page to access further information on acoustic performance.
Product properties:
| Name | Value |
| Product standard | EN 1366:3 2021+2024 and EN 1366-4:2021 |
| Fire performance | FirePro® AIS provides fire resistance of up to 4 hours (EI 240) in accordance with EN 1366-3: 2021 and EN 1366-4:2021, subject to the application. |
| Application temperature range | 5 - 35°C. |
| Shelf Life | 18 months. |
| Weighted Sound Reduction Index | Up to 62dB - please contact technical for further information on our acoustic performance. |
Specification:
- ROCKWOOL FirePro® AIS-Sealant. Pack of 25 - 310ml Cartridges. Colour: White
Installation:
We have technical representatives who provide assistance in the selection and specification of the products on this site and should be consulted for exact installation and product suitability. Ensure an early engagement with ourselves, designers, main contractor and specialist installers before any installation. Other trades and/or manufacturers may need to be consulted. For in-depth information, specification and technical advice please call our Head Office on Tel: +(0)1329 841416 or email sales@passivefireprotection.co.uk
Maintenance:
All interested parties, designer, specifier, main contractor and specialist installers should provide access to allow the fire stopping seals to be regularly inspected and maintained, as well as records kept of such maintenance at minimum periods of 12 months, as required by the Regulatory Reform Order, and repaired if necessary. Reference should be made to ASFP TGD 17 Code of Practice for the Installation and Inspection of Fire Stopping.
Competency:
It is vital that those entrusted to design or install a fire stopping product have the necessary levels of competence to undertake the task professionally and thoroughly. The level of competency required will be commensurate with the expected complexity of the building. All designers must eliminate, reduce or control foreseeable risks that may arise during installation, construction or maintenance when preparing or modifying designs. Clients should ensure that the principal designer and principal contractor carry out their duties under CDM regulations. The ASFP foundation course in passive fire protection provides essential knowledge as part of demonstrating competency and understanding in this key fire protection specialism.
Additional Notes:
Please refer to the UL-EU sheet for fields of application for this product. For further information on installation requirements please refer to the manufacturer of the services and the wall/floor specification to ensure the compatibility of this product, if in doubt please contact the technical team with services and wall/floor specification on Tel: +(0)1329 841416 or email sales@passivefireprotection.co.uk
Download and review any of the following information:
'UL Documentation' are 'UL - EU Certificate'
More certificates / test data available please contact us
Specifications
Ratings & Reviews
Write a review-
Be the first to review this product.

-1802-p.jpg?w=200&h=200&v=7249B93F-2069-4BFE-BD8D-D8C6851FFE09)
-1802-p.jpg?w=200&h=200&v=A4446EDF-7376-41E5-9BE4-E9E3F6B636EA)
-1802-p.jpg?w=200&h=200&v=4ACFBEA1-1F17-4916-A176-944DDB8A8AA5)
-1802-p.jpg?w=200&h=200&v=3E589A79-CAB4-4BD7-9B65-D949ACD64C5B)